Permit Info
Short Description:
3107 AC, 4035 SF, 2 STORY
Notes:
12/2/2019 5:50:42 PM
001. COMPLIANCE WITH THE AMENDED ZONING ORDINANCE (13-06-36) AND ALL DEED RESTRICTIONS SHOWN ON THE FINAL PLAT (DRIVEWAY; FENCE).
002. COMPLIANCE WITH THE 2015 BUILDING CODES, LOCAL AMENDMENTS, PD AND FINAL PLAT REQUIREMENTS.
003. TERMITE BARRIER PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. MAX SIDEWALK SLOPE IS 8.3%, ADD STEPS AS REQ'D.
016. BEAMS=10"W X 30"D.
029. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
033. ALL SIDING,TRIM,SHAKES AND SIMILAR NON-MASONRY EXTERIOR SURFACE COVERINGS MUST BE OF CEMENTITIOUS MATERIAL.
037. ATTIC STORAGE MUST NOT BE CONVERTED TO HABITABLE LIVING AREA WITHOUT A BUILDING PERMIT
042. TEMPERED GLASS REQUIRED AT WINDOWS AND PARTITIONS WITHIN 2' OF DOOR OPENINGS.
043. TEMPERED GLASS REQUIRED AT ALL BATHROOM HAZARD LOCATIONS, INCLUDING WINDOWS AND PARTITIONS IF GLAZING IS LESS THAN 60" ABOVE ANY STANDING/WALKING SURFACE.
044. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
045. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS. EMERGENCY/ESCAPE RESCUE OPENINGS SHALL HAVE NET CLEAR OPENING OF GREATER THAN OR EQUAL TO 5.7 SF. MINIMUM NET CLEAR HEIGHT OF 24" AND NET CLEAR WIDTH OF 20" (GRADE FLOOR OR BELOW GREATER THAN OR EQUAL TO 5.0SF).
050. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS
051. CO DETECTORS REQ'D ON ELECTRICAL LEGEND AND ELECTRICAL PLAN. (1) PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR AND OUTSIDE THE VICINITY OF EACH BEDROOM.
058. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
060. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PERMIT AND CONSTRUCTION.
061. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION AND (OR) ORNAMENTAL IRON AS PER PD REQUIREMENT.
*** IN SLEEPING ROOM WINDOW SILL HEIGHT FOR EMERGENCY ESCAPE AND RESCUE WINDDOW NOT TO EXCEED 44" ABOVE FLOOR. R310.2.2 ***
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
GARILEN PHASE 1B (CFR)
|
APPLICANT | DREES CUSTOM HOMES | (972)953-4500 | mvhebert@dreeshomes.com | 6225 SH 161 STE 100 | IRVING, TX 75038 |
OWNER | DREES CUSTOM HOMES LP | ()- | | | IRVING, TX 75038-2283 |
CONTRACTOR | DREES CUSTOM HOMES | (972)953-4500 | mvhebert@dreeshomes.com | 6225 SH 161 STE 100 | IRVING, TX 75038 |
ENGINEER | STRAND SYSTEMS ENGINEERING | (972)620-8204 | awalker@strandae.com | 10003 TECHNOLOGY BLVD | IRVING, TX 75039 |
HERS PROVIDE | TOPBUILD HOME SERVICES/TB HOME SERVICES | (386)304-2222 | LICENSEHELP@TRUTEAM.COM | 475 N WILLIAMSON BLVD | DAYTONA BEACH, FL 32114 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | awalker@strandae.com | 10003 TECHNOLOGY BLVD | IRVING, TX 75039 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
MECH. CTR. | A STAR HEAT & AIR INC (MECH) | (972)485-0813 | helen@astardfw.com | 10865 SANDEN DR | DALLAS, TX 75238 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP INC | (972)429-5575 | SCHEDULING@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
|
RESIDENTIAL BUILDING PERMIT FEE |
$1,706.20
|
|
FENCE FEE |
$20.00
|
|
RESIDENTIAL FEE |
$121.05
|
|
RESIDENTIAL MECHANICAL FEE |
$146.00
|
|
RESIDENTIAL PLUMBING FEE |
$270.00
|
|
THOROUGHFARE IMPACT FEE |
$997.00
|
|
WATER IMPACT FEE |
$1,772.00
|
|
SEWER IMPACT FEE |
$1,619.00
|
|
Total Fees |
Charged: $6,651.25
Balance Due: $6,651.25
|
There are currently no inspections on this record.
|
INITIAL REVIEW | KELLY EVANS | RECEIVED | 11/7/2019 | 11/7/2019 | 11/21/2019 |
More Info
|
RESIDENTIAL REVIEW | CAREY L FRAZIER | APPROVED AS NOTED | 11/7/2019 | 12/2/2019 | 11/21/2019 |
More Info
|