Permit Info
Short Description:
3046 AC, 3474 SQ FT, SFR / 2 STORY
Notes:
3046 AC, 3474 SQ FT, SFR / 2 STORY
7/18/2004 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
30. 1ST FLOOR WINDOW BOX-OUTS ONLY - AREA BOX-OUTS NOT ALLOWED.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
36. ENERGY STAR SUMMARY REPORT A.C. AREA MUST BE WITHIN 1% OF PERMIT / PLAN A.C. AREA.
39. MAX OF 24 SQ FT OF 6" GLASS BLOCK ALLOWED IN 1 HOUR FIRE RATED WALL ASSEMBLY.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
* 2' X 10' RULE ON CHIMNEY
* MEDIA ROOM NOT PART OF SUBMITTAL
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
LAKES ON LEGACY DRIVE #05, THE
|
OWNER | STERLING DESIGNS, INC-EXP 01/0 | (972)612-3405 | | 1424 GABLES CT #103 | PLANO, TX 75075 |
APPLICANT | STERLING DESIGNS, INC-EXP 01/0 | (972)612-3405 | | 1424 GABLES CT #103 | PLANO, TX 75075 |
CONTRACTOR | STERLING DESIGNS, INC-EXP 01/0 | (972)612-3405 | | 1424 GABLES CT #103 | PLANO, TX 75075 |
ELECT. CTR. | SORENSEN ELECTRIC X-11/04 | (972)578-9395 | | 1770 MILLARD #D | PLANO, TX 75074 |
GEN. CONTR. | STERLING DESIGNS, INC-EXP 01/0 | (972)612-3405 | | 1424 GABLES CT #103 | PLANO, TX 75075 |
IRRIGATION | CHOATE IRRIGATION X-01/31/2005 | (972)306-0755 | | P O BOX 118114 | CARROLLTON, TX 75011 |
MECH. CTR. | RELIANT A/C -EXP 06/04 | (972)864-9688 | | P.O. BOX 14849 | FT WORTH, TX 76117 |
PLUM. CONT. | D&M PLUMBING CONTRACTORS | (972)548-7954 | | 303 E. JOSEPHINE | MCKINNEY, TX 75069 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.