Permit Info
Short Description:
1845 A/C, 2660 SF, SFR / 1 STORY
Notes:
1845 A/C, 2660 SF, SFR / 1 STORY
3/29/2005 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
13. BEAMS=10"W X 32"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
BEAMS WITH 2-#5 REBAR IN THE BOTTOM OF EACH.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRIFFIN PARC # 02
|
OWNER | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
APPLICANT | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
CONTRACTOR | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
FENCE | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
GEN. CONTR. | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
IRRIGATION | GP & E (IRRIGATION) | (972)335-7373 | | 103 FM 423 | LITTLE ELM, TX 75068 |
MECH. CTR. | ESP SERVICES (ELEC) | (817)275-3505 | | 3500 PIONEER PARKWAY WEST | ARLINGTON, TX 76013 |
PLUM. CONT. | BCP PLUMBING X-09/05 | (817)481-0939 | | 611 E. DALLAS RD | GRAPEVINE, TX 76051 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/31/2005
| | 8/31/2005 | |
More Info
|