Permit Info
Short Description:
1 BF FIRE - 2421 AC, 3076 SQ FT, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
8/31/2017
Notes:
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
9. BEAMS=10"W X 26"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
41. TWO-HOUR FIRE SEPERATION REQUIRED.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(12/30/2003 15:15 SOM)NO PLUMBING IN FIREWALL
"GIFS" STUCCO SYSTEM IS NOT APPROVED FOR FRISCO RESIDENTIAL
1 BF FIRE - 2421 AC, 3076 SQ FT, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHASE AT STONEBRIAR THE (CFR)
|
BF TESTER | JEFF DENNEY | (214)779-5278 | | 8318 Ameras Cup | ROWLETT, TX 75089 |
OWNER | GOLDEN STATE/LONESTAR VENTURES | ()- | | | FRISCO, TX 75034-6825 |
MAIL TO | GOLDEN STATE/LONESTAR VENTURES | ()- | | | FRISCO, TX 75034-6825 |
APPLICANT | STANDARD PACIFIC (GEN) X-1/04 | (214)387-8886 | | 5525 MCARTHUR | IRVING, TX 75038 |
CONTRACTOR | STANDARD PACIFIC (GEN) X-1/04 | (214)387-8886 | | 5525 MCARTHUR | IRVING, TX 75038 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 3521 W. GILBERT RD | GRAND PRAIRIE, TX 75050 |
GEN. CONTR. | STANDARD PACIFIC (GEN) X-1/04 | (214)387-8886 | | 5525 MCARTHUR | IRVING, TX 75038 |
IRRIGATION | ML JOHNSON (IRRI) X 04/05 | (972)442-2594 | | P.O. BOX 460897 | GARLAND, TX 75046 |
MECH. CTR. | BELLAIR HEATING & COOLING | (972)731-0376 | | P.O. BOX 1988 | FRISCO, TX 75034 |
PLUM. CONT. | BCP PLUMBING X-1/04 | (817)481-0939 | | 611 E. DALLAS RD | GRAPEVINE, TX 76051 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/31/2016
| | 8/31/2016 | |
More Info
|
BACKFLOW | APPROVED |
12/20/2004
| | 12/20/2004 | |
More Info
|
There are currently no reviews on this record.