Permit Info
Short Description:
2486 AC, 3662 SQ FT, SFR / 2 STORY
Notes:
2486 AC, 3662 SQ FT, SFR / 2 STORY
6/29/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
11. BEAMS=10"W X 29"D.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(06/29/2004 14:51 JC)House w/ (3) car garage.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
TRAILS # 10, THE
|
OWNER | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
APPLICANT | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
CONTRACTOR | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
IRRIGATION | NORTH TEXAS LAWN & LANDSCAPE | (972)240-8082 | | P.O. BOX 2140 | ROCKWALL, TX 75087 |
MECH. CTR. | AIRTRON | (972)276-2117 | | 208 SOUTH INTERNATIONAL RD. | GARLAND, TX 75042 |
PLUM. CONT. | ENTERPRISE PLUMBING X-1/05 | (972)231-2860 | | 900 ALPHA #430 | RICHARDSON, TX 75081 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.