Permit Info
Short Description:
1871 AC, 2350 SQ FT, SFR / 1 STORY
Notes:
1871 AC, 2350 SQ FT, SFR / 1 STORY
2/3/2005 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
9. BEAMS=10"W X 26"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
38. 1 HOUR FIRE WALL ASSEMBLY REQ'D - SUBMIT DESIGN PRIOR TO WALL CONSTRUCTION.
39. MAX OF 24 SQ FT OF 6" GLASS BLOCK ALLOWED IN 1 HOUR FIRE RATED WALL ASSEMBLY.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(02/03/2005 10:15 JC)2nd. floor w/ (2) bedrooms, (2) baths and game room.
Parcel Info
City/State/Zip:
TX, 75034
Subdivision:
CHAPEL CREEK #1B
|
OWNER | ROBERT BALKMAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATIONS SUITE 100 | PLANO, TX 75093 |
APPLICANT | ROBERT BALKMAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATIONS SUITE 100 | PLANO, TX 75093 |
CONTRACTOR | ROBERT BALKMAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATIONS SUITE 100 | PLANO, TX 75093 |
ELECT. CTR. | ARI-TEX ELECTRIC INC X-9/04 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
GEN. CONTR. | ROBERT BALKMAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATIONS SUITE 100 | PLANO, TX 75093 |
IRRIGATION | TEXAS WATERBOYS, INC X-08/2006 | (972)733-4343 | | P.O. BOX 797068 | DALLAS, TX 75379 |
MECH. CTR. | CHAPMAN AIR & HEAT X-02/05 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RELIABLE PLUMBING X- 08/05 | (972)285-0939 | | 2509 FRANKLIN | MESQUITE, TX 75150 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/13/2004
| | 10/13/2004 | |
More Info
|
There are currently no reviews on this record.