Permit Info
Short Description:
2401 AC, 2865 SQ FT, SFR / 2 STORY
Notes:
2401 AC, 2865 SQ FT, SFR / 2 STORY
10/29/2003 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
9. BEAMS=10"W X 26"D.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
51. "ASCE" REQUIRES TOP AND / OR BOTTOM BEAM REBAR PER 5.2.2.3 d.
55. ENGINEER OF RECORD FRAMING DESIGN SUPERSEDES BUILDERS DESIGN PLANS.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(10/29/2003 10:51 MBW)REQUIRED 2 STORY SHEAR WALL TIE DESIGN MISSING AND CHIMNEY FRAME DESIGN.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STEWART CREEK ESTATES #01
|
OWNER | BOWEN BUILDERS GROUP | (214)544-2442 | | 131 S. TENNESSEE | MCKINNEY, TX 75069 |
APPLICANT | BOWEN BUILDERS GROUP | (214)544-2442 | | 131 S. TENNESSEE | MCKINNEY, TX 75069 |
CONTRACTOR | BOWEN BUILDERS GROUP | (214)544-2442 | | 131 S. TENNESSEE | MCKINNEY, TX 75069 |
ELECT. CTR. | HOUSTON STAFFORD ELECTRIC X- 1 | (972)463-1455 | | 2500 CHANDLER DR. | ROWLETT, TX 75088 |
GEN. CONTR. | BOWEN BUILDERS GROUP | (214)544-2442 | | 131 S. TENNESSEE | MCKINNEY, TX 75069 |
IRRIGATION | CHOATE IRRIGATION X-01/31/2005 | (972)306-0755 | | P O BOX 118114 | CARROLLTON, TX 75011 |
MECH. CTR. | AIRTRON | (972)276-2117 | | 208 SOUTH INTERNATIONAL RD. | GARLAND, TX 75042 |
PLUM. CONT. | ABC PLUMBING, INC. | (972)423-7477 | | 1104 CAPITAL | PLANO, TX 75074 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.