Permit Info
Short Description:
2214 AC, 3187 SF, SFR / 1 STORY
Notes:
2214 AC, 3187 SF, SFR / 1 STORY
6/8/2005 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
13. BEAMS=10"W X 32"D.
BEAMS WITH 2-#5 REBAR IN THE BOTTOM OF ALL BEAMS.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
GRIFFIN PARC # 02
|
OWNER | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
APPLICANT | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
CONTRACTOR | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
ELECT. CTR. | MASTER ELECTRICAL SYSTEM X-8/ | (972)323-9243 | | P O BOX 112608 | CARROLLTON, TX 75011 |
GEN. CONTR. | CAMBRIDGE HOMES, INC. | (972)478-8181 | | 2828 TRINITY MILLS, SUITE 300 | CARROLLTON, TX 75006 |
IRRIGATION | GP & E (IRRIGATION) | (972)335-7373 | | 103 FM 423 | LITTLE ELM, TX 75068 |
MECH. CTR. | ESP SERVICES (MECH) X-12/05 | (817)275-3505 | | 3500 PIONEER PARKWAY | ARLINGTON, TX 76013 |
PLUM. CONT. | BCP PLUMBING X-09/05 | (817)664-2091 | | 1313 KNIGHT STREET | ARLINGTON, TX 76015 |
STRUCT ENG | GRAHAM - MARTIN, LTD. | (972)647-1025 | BILL@GRAHAM-MARTIN.COM | 2100 N. HWY 360, SUITE 201 | GRAND PRAIRIE, TX 75050 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no reviews on this record.