Permit Info
Short Description:
2477 AC, 2915 SF, SFR / 2 STORY
Notes:
(06/16/2005 15:52 JC)
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
09. BEAMS=10"W X 26"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
56. LETTERS OF ACCEPTANCE REQUIRED FROM BOTH ENGINEERS FOR CO.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(06/16/2005 15:52 JC)
2nd. story with bonus room only.
2477 AC, 2915 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
MEADOW CREEK
|
OWNER | RYLAND HOMES | (972)629-8210 | | 17855 NORTH DALLAS PKWY., STE | DALLAS, TX 75287 |
APPLICANT | RYLAND HOMES | (972)629-8210 | | 17855 NORTH DALLAS PKWY., STE | DALLAS, TX 75287 |
CONTRACTOR | RYLAND HOMES | (972)629-8210 | | 17855 NORTH DALLAS PKWY., STE | DALLAS, TX 75287 |
ELECT. CTR. | C & B ELECTRIC X-12/05 | (972)790-0707 | | 3521 W. GILBERT RD | GRAND PRAIRIE, TX 75050 |
GEN. CONTR. | RYLAND HOMES | (972)629-8210 | | 17855 NORTH DALLAS PKWY., STE | DALLAS, TX 75287 |
IRRIGATION | RIVERSIDE IRRIGATION 09/05 | (972)647-8398 | | P.O. BOX 200755 | ARLINGTON, TX 76006 |
MECH. CTR. | NORTH TEXAS AIRCO, INC. X- 3/ | (972)436-4010 | | 965 E. HWY 121 | LEWISVILLE, TX 75057 |
PLUM. CONT. | ZINNA PLUMBING, INC. X-9/05 | ()- | | 4900 PRESTON | FRISCO, TX |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | sdickson@de-structures.com | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.