Permit Info
Short Description:
4219 A/C , 5163 SF, SFR / 2 STORY
Notes:
4219 A/C , 5163 SF, SFR / 2 STORY
2/3/2005 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
11. BEAMS=10"W X 29"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
(02/03/2005 09:54 JC)Driller piers : (5) #4 (or) (4) #5 vertical rebar.
Parcel Info
City/State/Zip:
TX, 75034
Subdivision:
TRAILS # 07, THE
|
OWNER | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
APPLICANT | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DARLING HOMES | (972)624-4100 | | 2500 LEGACY #100 | FRISCO, TX 75034 |
MECH. CTR. | JOPLINS COMPRESSOR SVC X-10/0 | (972)569-8339 | | 301 E MIDWAY | McKinney, TX 75069 |
PLUM. CONT. | ABC HEATING & AIR X-9/05 | (972)423-7380 | | P.O. BOX 260104 | PLANO, TX 75026 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.