Permit Info
Short Description:
3922 AC, 5039 SQ FT, SFR / 1 STORY
Notes:
3922 AC, 5039 SQ FT, SFR / 1 STORY
8/3/2004 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
9. BEAMS=10"W X 26"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
40. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
TX, 75034
Subdivision:
VILLAGES OF STONEBRIAR PARK #2
|
OWNER | EMORY WALKER | (972)624-0046 | | 6408 STONE CANYON DR | PLANO, TX 75024 |
APPLICANT | STEPHENSON CUSTOM BUILDERS, IN | (972)713-6898 | | 5068 W PLANO PKWY #175 | Plano, TX 75093 |
CONTRACTOR | STEPHENSON CUSTOM BUILDERS, IN | (972)713-6898 | | 5068 W PLANO PKWY #175 | Plano, TX 75093 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
GEN. CONTR. | STEPHENSON CUSTOM BUILDERS, IN | (972)713-6898 | | 5068 W PLANO PKWY #175 | Plano, TX 75093 |
IRRIGATION | TEXAS WATERBOYS, INC X-03/2005 | (972)733-4343 | | P.O. BOX 797068 | DALLAS, TX 75379 |
MECH. CTR. | ENVIROMENTAL CONTROLS X-07/04 | (972)249-9982 | | 901 N. MILL #203 | LEWISVILLE, TX 75057 |
PLUM. CONT. | TERRELL PLUMBING | (972)424-6274 | | 1208 14TH | PLANO, TX 75074 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.
There are currently no reviews on this record.