Permit Info
Short Description:
1 BF FIRE PROT- 6459 AC, 8292 SQ FT, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
4/13/2017
Notes:
1 BF FIRE PROT- 6459 AC, 8292 SQ FT, SFR / 2 STORY
7/18/2004 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
30. 1ST FLOOR WINDOW BOX-OUTS ONLY - AREA BOX-OUTS NOT ALLOWED.
31. SIDING OVER MASONRY AT SECOND STORY NOT ALLOWED.
32. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
51. "ASCE" REQUIRES TOP AND / OR BOTTOM BEAM REBAR PER 5.2.2.3 d.
53. ANY CHANGES FROM THE APPROVED PLAN ON FILE WITHOUT PRIOR AUTHORIZATION WILL VOID THIS PERMIT.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
* BRICK W/ WOOD TRIM FRONT 2 GABLES
* 2' X 10' RULE AT CHIMNEY
* ADDITIONAL BDRM U/S W/ BATH NOT INCLUDED
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE NO. 16 (CFR)
|
BF TESTER | PATRICK W ODOM | (214)418-0684 | METROFIRE@MFPDALLASINC.COM | 279 LEE STREET | EDGEWOOD, TX 75117 |
OWNER | FENTON BRAD | ()- | | | FRISCO, TX 75034-2245 |
MAIL TO | FENTON BRAD | ()- | | | FRISCO, TX 75034-2245 |
APPLICANT | Drais Custom Homes | (972)978-2678 | | 6725 Banyan | Plano, TX 75023 |
CONTRACTOR | Drais Custom Homes | (972)978-2678 | | 6725 Banyan | Plano, TX 75023 |
ELECT. CTR. | GRACE ELECTRIC | (214)222-3902 | | 720 VALLEY RIDGE # 16 | LEWISVILLE, TX 75057 |
FENCE | DECKER SERVICES CO., INC. X-5/ | (214)496-0722 | | 904 BANDERA CT. | ALLEN, TX 75013 |
GEN. CONTR. | Drais Custom Homes | (972)978-2678 | | 6725 Banyan | Plano, TX 75023 |
IRRIGATION | DIGITAL RAIN (IRRI) | (972)346-3999 | | 3793 PHEASANT RUN (IRRI) | CELINA, TX 75009 |
MECH. CTR. | CHAPMAN AIR & HEAT X-02/20 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RD PLUMBING SERVICES X-07/0 | (972)636-7993 | | 469 STREETMAN RD | ROYCE CITY, TX 75189 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/13/2016
| | 4/13/2016 | |
More Info
|
There are currently no reviews on this record.