Permit Info
Short Description:
5110 AC, 6213 SQ FT, SFR / 2 STORY
Notes:
5110 AC, 6213 SQ FT, SFR / 2 STORY
8/20/2004 12:00:00 AM
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
* 2ND FLOOR W/ 3 BRS, 2 BATHS, GAME ROOM AND MEDIA ROOM
NOTE:
IF NON AC SPACE IS PLANNED FOR FUTURE AC SPACE, THIS HOUSE MAY NEED SPRINKLERS.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #04 VILLAGE NO. 16
|
OWNER | MURPHY BUILDING C | (972)596-2331 | | PO BOX 866004 | Plano, TX 75086 |
APPLICANT | MURPHY BUILDING C | (972)596-2331 | | PO BOX 866004 | Plano, TX 75086 |
ELECT. CTR. | ML HAMILTON ELECTRIC | (972)725-7512 | | P O BOX 18 | ALLEN, TX 75013 |
GEN. CONTR. | MURPHY BUILDING C | (972)596-2331 | | PO BOX 866004 | Plano, TX 75086 |
IRRIGATION | A & A LANDSCAPE & IRRGTN | (972)784-7950 | | 13758 HWY 380 | FARMERSVILLE, TX 75442 |
MECH. CTR. | KRUGERS HEAT'G & A/C | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | MEDLOCK PLUMBING-EXP 06/05 | (972)734-3674 | | 9587 C.R. 392 | PRINCETON, TX 75407 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
There are currently no inspections on this record.