Permit Info
Short Description:
1 BF FIRE PROT; 9108 SF, SFR / 2 STORY
Expiration Date:
9/28/2018
Notes:
1 BF FIRE PROT; 9108 SF, SFR / 2 STORY
3/9/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
TWO #4'S AT THE BOTTOM OF ALL BEAMS WITHOUT 2-BEAM STRANDS.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #6 VILLAGES NO 19 & 20 (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | WALSH LISA M & MARTIN | ()- | | | FRISCO, TX 75034-5223 |
MAIL TO | WALSH LISA M & MARTIN | ()- | | | FRISCO, TX 75034-5223 |
APPLICANT | REYNOLDS SIGNATURE HOMES | (214)908-5950 | | 6364 CAROLINE DR | FRISCO, TX 75034 |
CONTRACTOR | REYNOLDS SIGNATURE HOMES | (214)908-5950 | | 6364 CAROLINE DR | FRISCO, TX 75034 |
ELECT. CTR. | MEGA ELECTRIC CO., INC. X-1 | (972)727-8263 | | P.O. BOX 757 | ALLEN, TX 75013 |
GEN. CONTR. | REYNOLDS SIGNATURE HOMES | (214)908-5950 | | 6364 CAROLINE DR | FRISCO, TX 75034 |
HERS PROVIDE | ENERGY SENSE X-02-06 | (214)341-0668 | jason.mcalister@mascocs.com | 11111 PLANO ROAD | DALLAS, TX 75238 |
MECH. CTR. | JOE COOK HVAC X-5/05 | (972)494-2665 | | 309 W. AVENUE "A" | GARLAND, TX 75090 |
PLUM. CONT. | RIDDELL PLUMBING, INC. X 2/07 | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
STRUCT ENG | PARAGON STRUCTURAL ENGINEERING | (214)941-8350 | brian@pseglobal.com | 5068 W PLANO PKWY, SUITE 199 | PLANO, TX 75093 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/8/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/6/2017
| | 12/6/2017 | |
More Info
|
BACKFLOW | APPROVED |
9/28/2016
| | 9/28/2016 | |
More Info
|
BACKFLOW | APPROVED |
3/1/2007
| | 3/1/2007 | |
More Info
|
There are currently no reviews on this record.