Permit Info
Short Description:
1 FIRE BF--5948 AC, 7388 SF, SFR / 2 STORY
Expiration Date:
8/30/2018
Notes:
1 FIRE BF--5948 AC, 7388 SF, SFR / 2 STORY
10/11/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10. BEAMS=10"W X 28"D.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
45. SIDEYARD SET-BACK ENCROACHMENT AT BOX-OUTS LIMITED TO 12".
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 6A
|
BF TESTER | JEFFREY WORLEY | (972)699-7156 | | 1662 CR 1020 | RAVENNA, TX 75476 |
OWNER | JANCOWSKI, LUIS A | ()- | | | FRISCO, TX 75033 |
MAIL TO | JANCOWSKI, LUIS A | ()- | | | FRISCO, TX 75033 |
APPLICANT | RIVERA CUSTOM HOMES X-9/07 | (214)502-0773 | | 4537 HIGHLAND PARK, # 200 | DALLAS, TX 75205 |
CONTRACTOR | RIVERA CUSTOM HOMES X-9/07 | (214)502-0773 | | 4537 HIGHLAND PARK, # 200 | DALLAS, TX 75205 |
ELECT. CTR. | MEGA ELECTRIC CO., INC. X-1 | (972)727-8263 | | P.O. BOX 757 | ALLEN, TX 75013 |
GEN. CONTR. | RIVERA CUSTOM HOMES X-9/07 | (214)502-0773 | | 4537 HIGHLAND PARK, # 200 | DALLAS, TX 75205 |
HERS PROVIDE | 1ST RATE BUILDING & ENERGY CON | (972)575-8320 | info@test-inspect.com | P.O. BOX 933 | WYLIE, TX 75098 |
MECH. CTR. | ABC HEATING & AIR X-9/07 | (972)423-7380 | | P.O. BOX 260104 | PLANO, TX 75026 |
PLUM. CONT. | FOUR STAR PLUMBING X-2/2007 | (972)306-9300 | | 4301 REEDER DR # 100 | CARROLLTON, TX 75010 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
9/29/2017
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/21/2017
| | 9/21/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/30/2016
| | 8/30/2016 | |
More Info
|
BACKFLOW | APPROVED |
4/11/2007
| | 4/11/2007 | |
More Info
|
There are currently no reviews on this record.