Permit Info
Short Description:
1BF FIRE PROT. 6872 AC, 8409 SF, SFR / 2 STORY W/BASEMENT
Expiration Date:
6/13/2018
Notes:
1BF FIRE PROT. 6872 AC, 8409 SF, SFR / 2 STORY W/BASEMENT
7/13/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(7/13/2006 07:01 JC)
Max. structure height to highest ridge is 40'-0" from average finish grade.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | CHRISTOPHER GAFFORD | (972)242-2229 | | 2605 DAISY LANE | ROWlETT, TX 75089 |
OWNER | STEINHEISER SYLVIA & | ()- | | MICHAEL STEINHEISER | FRISCO, TX 75034-7437 |
MAIL TO | STEINHEISER SYLVIA & | ()- | | MICHAEL STEINHEISER | FRISCO, TX 75034-7437 |
APPLICANT | SHELDON D. ROBINSON CUSTOM HOM | ()- | SHELDON@THECUSTOMEBUILDER.COM | 232 FIVE K RANCH DR. | VAN ALSTYNE, TX 75495 |
CONTRACTOR | SHELDON D. ROBINSON CUSTOM HOM | ()- | SHELDON@THECUSTOMEBUILDER.COM | 232 FIVE K RANCH DR. | VAN ALSTYNE, TX 75495 |
ELECT. CTR. | ARI-TEX ELECTRIC INC X- 10/20 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
GEN. CONTR. | SHELDON D. ROBINSON CUSTOM HOM | ()- | SHELDON@THECUSTOMEBUILDER.COM | 232 FIVE K RANCH DR. | VAN ALSTYNE, TX 75495 |
HERS PROVIDE | ENERGY SENSE X-02-06 | (214)341-0668 | jason.mcalister@mascocs.com | 11111 PLANO ROAD | DALLAS, TX 75238 |
MECH. CTR. | LUKES HEATING & AIR X-06/06 | (972)519-1987 | | 2903 LAGUNA | Plano, TX 75025 |
PLUM. CONT. | RIDDELL PLUMBING, INC. X 2/08 | (972)682-4860 | | 3700 US HIGHWAY 80 EAST | MESQUITE, TX 75149 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/27/2017
|
BACK FLOW FORM REVIEW |
$0.00
|
|
BACK FLOW FORM REVIEW |
$25.00
|
6/16/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
6/13/2017
| | 6/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/23/2017
| | 1/23/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/24/2007
| | 4/24/2007 | |
More Info
|
There are currently no reviews on this record.