Permit Info
Short Description:
1 BF FIRE PROT-, 7857 SF, SFR / 2 STORY
Expiration Date:
5/24/2019
Notes:
1 BF FIRE PROT-, 7857 SF, SFR / 2 STORY
3/14/2005 12:00:00 AM
1. ***ENERGY STAR***
2. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
3. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
12. BEAMS=10"W X 30"D.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
35. 2 X 6 PLUMBING (VENT STACK/WASTE)WALLS REQ'D.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
* 2ND FLOOR WINDOW EGRESS 5'7".
* 2ND LEVEL WITH 3 BDRMS, 3.5 BATHS, MEDIA ROOM AND GAME ROOM.
(6/1/2006 11:41 MEV) CREDIT $35.00 TO BO5-1664, PULLED IN ERROR .
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
VILLAGES OF STONEBRIAR PARK #2 (CFR)
|
BF TESTER | DARREN LEVESCY | (214)223-7250 | DARREN.LEVESCY@AFPGUSA.US | 202 BROOKHOLLOW DR | TERRELL, TX 75160 |
OWNER | ROE RANDY D & MARCY | ()- | | | FRISCO, TX 75034-1859 |
MAIL TO | ROE RANDY D & MARCY | ()- | | | FRISCO, TX 75034-1859 |
APPLICANT | PHIPPS & CO. | (972)407-1970 | | 17000 PRESTON RD STE. 200 | DALLAS, TX 75248 |
CONTRACTOR | PHIPPS & CO. | (972)407-1970 | | 17000 PRESTON RD STE. 200 | DALLAS, TX 75248 |
ELECT. CTR. | SORENSEN ELECTRIC X-01/06 | (972)578-9395 | | 1770 MILLARD #D | PLANO, TX 75074 |
GEN. CONTR. | PHIPPS & CO. | (972)407-1970 | | 17000 PRESTON RD STE. 200 | DALLAS, TX 75248 |
IRRIGATION | CHOATE IRRIGATION X-6/2006 | (972)306-0755 | | P O BOX 118114 | CARROLLTON, TX 75011 |
MECH. CTR. | KRUGERS HEAT'G & A/C | (972)276-3109 | | 1409 S JUPITER RD | GARLAND, TX 75042 |
PLUM. CONT. | FRITZ PLUMBING (PLUM) X-1/05 | (972)335-3560 | | P.O. BOX 194 | FRISCO, TX 75034 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/8/2018
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/26/2018
| | 5/8/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/24/2007
| | 5/24/2007 | |
More Info
|
There are currently no reviews on this record.