Permit Info
Short Description:
1 bf fire 8970 AC, 11714 SF, SFR / 2 STORY
Expiration Date:
8/2/2018
Notes:
1 bf fire 8970 AC, 11714 SF, SFR / 2 STORY
5/2/2006 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
08. BEAMS=10"W X 24"D.
20. W/12" DIA. PIERS W/(1) #5 REBAR
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
2ND FLOOR: 3 BEDROOMS, 3 BATHS, GAME ROOM, WET BAR AND ELEVATOR SHAFT WITH 1 HOUR RATED WALLS.
DRIVEWAY CANNOT EXCEED 12% - CONFIRM ON PLOT PLAN.
SEE ELEVATOR COMPANY FOR 1 HOUR RATED WALL DETAIL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD #4 VILLAGE #17 (CFR)
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | BEHAN WILLIAM B & CATHERINE L | ()- | | | FRISCO, TX 75034-4087 |
MAIL TO | BEHAN WILLIAM B & CATHERINE L | ()- | | | FRISCO, TX 75034-4087 |
APPLICANT | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
CONTRACTOR | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
ELECT. CTR. | HAMILTON PLUMBING X-04/2007 | (972)423-6361 | | 1901 COUNTRY CLUB | PLANO, TX 75074 |
GEN. CONTR. | LONNIE GRAY CUSTOM | (972)624-1616 | | P.O. BOX 796621 | DALLAS, TX 75379 |
MECH. CTR. | ABC HEATING & AIR X-9/06 | (972)423-7380 | | P.O. BOX 260104 | PLANO, TX 75026 |
PLUM. CONT. | RIDDELL PLUMBING, INC. X 2/07 | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/11/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
8/2/2016
|
CREDIT CARD FEE |
$0.50
|
8/2/2016
|
Total Fees |
Charged: $50.50
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/4/2017
| | 10/4/2017 | |
More Info
|
BACKFLOW | APPROVED |
8/2/2016
| | 8/2/2016 | |
More Info
|
BACKFLOW | APPROVED |
5/24/2007
| | 5/24/2007 | |
More Info
|
There are currently no reviews on this record.