Permit Info
Short Description:
1 BF FIRE PROT--6964 AC, 8650 SF, SFR / 2 STORY
Expiration Date:
1/28/2019
Notes:
1 BF FIRE PROT--6964 AC, 8650 SF, SFR / 2 STORY
8/4/2006 12:00:00 AM
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
09. BEAMS=10"W X 26"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2' & 10' RULE WILL APPLY TO ALL CHIMNEYS ADJACENT TO ANY ROOFLINE
2ND LEVEL: 3 BDRM. 3 BA. SITTING RM. GAME RM.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #1 (CFR)
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | GOVINDJI YOGESH & SWAPNA | ()- | | | FRISCO, TX 75034-7243 |
MAIL TO | GOVINDJI YOGESH & SWAPNA | ()- | | | FRISCO, TX 75034-7243 |
APPLICANT | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
CONTRACTOR | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
ELECT. CTR. | ARI-TEX ELECTRIC INC X- 10/20 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
GEN. CONTR. | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
MECH. CTR. | CHAPMAN AIR & HEAT X-04/20 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RELIABLE PLUMBING X- 09/2006 | (972)285-0939 | | 2509 FRANKLIN | MESQUITE, TX 75150 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/22/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
2/1/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/19/2018
| | 1/19/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/28/2017
| | 2/28/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/29/2016
| | 1/29/2016 | |
More Info
|
BACKFLOW | APPROVED |
6/13/2007
| | 6/13/2007 | |
More Info
|
There are currently no reviews on this record.