Permit Info
Short Description:
1 BF FIRE PROT - 6628 AC, 8254 SF, SFR / 2 STORY
Expiration Date:
1/8/2019
Notes:
1 BF FIRE PROT - 6628 AC, 8254 SF, SFR / 2 STORY
2/13/2006 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
28. TEMPERED GLASS REQ'D AT WINDOW ADJ TO STAIR.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2nd FLOOR: 3-BED ROOMS,3-BATHS,UPPER FOYER,GALLERY,FAMILY ROOM AND PLAY CENTER.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #1 (CFR)
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | ABRAHAM CHRIS RAYMOND & TIFFAN | ()- | | | FRISCO, TX 75034-7253 |
MAIL TO | ABRAHAM CHRIS RAYMOND & TIFFAN | ()- | | | FRISCO, TX 75034-7253 |
APPLICANT | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
CONTRACTOR | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
ELECT. CTR. | ML HAMILTON ELECTRIC X-08/2006 | (972)725-7512 | | P O BOX 18 | ALLEN, TX 75013 |
GEN. CONTR. | CLASSICAL CUSTOM HOMES X- 3/04 | (972)208-4098 | | P.O. BOX 863809 | PLANO, TX 75086 |
IRRIGATION | EARTH GROUP (IRRI) | (972)985-9541 | | 3349 CANYON VALLEY TRAIL | PLANO, TX 75023 |
MECH. CTR. | HOUK AIR CONDITIONING X-05/200 | (817)265-1191 | | 128 FAIRVIEW | ARLINGTON, TX 76010 |
PLUM. CONT. | RIDDELL PLUMBING, INC. x -10/ | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
1/17/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/12/2018
| | 1/12/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/17/2017
| | 1/17/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/8/2016
| | 1/8/2016 | |
More Info
|
BACKFLOW | APPROVED |
5/24/2007
| | 5/24/2007 | |
More Info
|
There are currently no reviews on this record.