Permit Info
Short Description:
1 BF FIRE--6141 AC, 7793 SF, SFR / 2 STORY
Expiration Date:
1/8/2019
Notes:
1 BF FIRE--6141 AC, 7793 SF, SFR / 2 STORY
10/10/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
23. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
44. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN PLUS (1) ADD'L AT GARAGE ENTRY IN AC AREA.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | STEWART WADE A & CARRIE J | ()- | | | FRISCO, TX 75034-7283 |
MAIL TO | STEWART WADE A & CARRIE J | ()- | | | FRISCO, TX 75034-7283 |
APPLICANT | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
ELECT. CTR. | PROFESSIONAL PLUMBERS X-02/200 | (972)429-5575 | | 1322 CENTURY WAY | WYLIE, TX 75098 |
GEN. CONTR. | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
HERS PROVIDE | C & C ENGINEERING (H.E.R.S. PR | (512)467-0005 | ENERGY@CNCENG.COM | 8868 RESEARCH BLVD, SUITE 103 | AUSTIN, TX 78758 |
PLUM. CONT. | GRACE ELECTRIC X-12 | (214)222-3902 | | 720 VALLEY RIDGE # 16 | LEWISVILLE, TX 75057 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING - X | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/17/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/11/2018
| | 1/11/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/9/2017
| | 1/9/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/8/2016
| | 1/8/2016 | |
More Info
|
BACKFLOW | APPROVED |
7/18/2007
| | 7/18/2007 | |
More Info
|
There are currently no reviews on this record.