Permit Info
Short Description:
1 BF FIRE PROT. 6939 SF, SFR / 2 STORY
Expiration Date:
1/13/2019
Notes:
1 BF FIRE PROT. 6939 SF, SFR / 2 STORY
1/26/2007 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
24. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | DARROW DOUGLAS J & RUTH A | ()- | | | FRISCO, TX 75034-7281 |
MAIL TO | DARROW DOUGLAS J & RUTH A | ()- | | | FRISCO, TX 75034-7281 |
APPLICANT | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
ELECT. CTR. | FOX ELECTRIC X-1/08 | (817)461-2571 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | DARLING HOMES - X 8/07 | (972)624-4100 | | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
IRRIGATION | LAKESIDE IRRIGATION | (972)722-8020 | | 504 WILLOW SPRINGS DR. | HEATH, TX 75032 |
MECH. CTR. | BILL JOPLIN'S COMPRESSOR SRVC | (972)569-8339 | | 301 E. MIDWAY STREET | McKINNEY, TX 75069 |
PLUM. CONT. | FRITZ PLUMBING (PLUM) X-1/07 | (972)335-3560 | | P.O. BOX 194 | FRISCO, TX 75034 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING - X | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/20/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/9/2018
| | 1/9/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/13/2017
| | 1/13/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/22/2016
| | 1/22/2016 | |
More Info
|
BACKFLOW | APPROVED |
8/1/2007
| | 8/1/2007 | |
More Info
|
There are currently no reviews on this record.