Permit Info
Short Description:
1 BF FIRE PROT--8253 AC, 10904 SF, SFR / 2 STORY **MODEL**
Expiration Date:
3/17/2019
Notes:
1 BF FIRE PROT--8253 AC, 10904 SF, SFR / 2 STORY **MODEL**
2/11/2006 12:00:00 AM
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
09. BEAMS=10"W X 26"D.
22. W/12" DIA. PIERS W/(3) #5 REBAR
25. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
27. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHES CLOSET MUST HAVE OPERABLE WINDOW.
34. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
58. 12 SEER ALONG WITH R-6 DUCT WORK REQ'D FOR 2000 IECC COMPLIANCE IN NON ENERGY STAR/GREEN BLDG CONSTRUCTION.
59. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
THE DRIVEWAY MUST NOT EXCEED 12% GRADIENT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STARWOOD PHASE FOUR VILLAGE NO 17 (CFR)
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | VISWANATHAN SIDDHARTH & ARCHANA S NAIR | ()- | | | FRISCO, TX 75034-4076 |
MAIL TO | VISWANATHAN SIDDHARTH & ARCHANA S NAIR | ()- | | | FRISCO, TX 75034-4076 |
APPLICANT | BELLA CUSTOM HOMES | (972)250-0898 | | PO BoX 516 | ADDISON, TX 75001 |
CONTRACTOR | BELLA CUSTOM HOMES | (972)250-0898 | | PO BoX 516 | ADDISON, TX 75001 |
ELECT. CTR. | JW ELECTRIC X-01/07 | (817)795-0858 | | 2900 E. RANDOL MILL RD. | ARLINGTON, TX 76011 |
GEN. CONTR. | BELLA CUSTOM HOMES | (972)250-0898 | | PO BoX 516 | ADDISON, TX 75001 |
MECH. CTR. | CHAPMAN AIR & HEAT X-04/20 | (214)340-4999 | | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RRC PLUMBING, LLC X-6/2006 | (972)569-9997 | | 601 ISLEWORTH LANE | MCKINNEY, TX 75070 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
3/12/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/17/2017
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/6/2018
| | 3/6/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/10/2017
| | 5/10/2017 | |
More Info
|
BACKFLOW | APPROVED |
3/17/2016
| | 3/17/2016 | |
More Info
|
BACKFLOW | APPROVED |
8/8/2007
| | 8/8/2007 | |
More Info
|
There are currently no reviews on this record.