Permit Info
Short Description:
1 FIRE BF PROT--5261 AC, 6645 SF, SFR / 2 STORY BF TEST
Expiration Date:
1/20/2019
Notes:
1 FIRE BF PROT--5261 AC, 6645 SF, SFR / 2 STORY BF TEST
1/16/2007 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
12. BEAMS=10"W X 30"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
33. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
35. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
42. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | BRIAN L. HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | CHASTAIN CHRISTOPHER R & DANA | ()- | | | FRISCO, TX 75034-5879 |
MAIL TO | CHASTAIN CHRISTOPHER R & DANA | ()- | | | FRISCO, TX 75034-5879 |
APPLICANT | SANDERS & ASSOCX-03/03 | (972)713-8494 | | 12850 HILLCREST, SUITE 200 | DALLAS, TX 75230 |
CONTRACTOR | SANDERS & ASSOCX-03/03 | (972)713-8494 | | 12850 HILLCREST, SUITE 200 | DALLAS, TX 75230 |
GEN. CONTR. | SANDERS & ASSOCX-03/03 | (972)713-8494 | | 12850 HILLCREST, SUITE 200 | DALLAS, TX 75230 |
HERS PROVIDE | C & C ENGINEERING (H.E.R.S. PR | (512)467-0005 | ENERGY@CNCENG.COM | 8868 RESEARCH BLVD, SUITE 103 | AUSTIN, TX 78758 |
IRRIGATION | CHOATE IRRIGATION X-07/2008 | (972)306-0755 | BUILDER | P O BOX 118114 | CARROLLTON, TX 75011 |
MECH. CTR. | HOUK AIR CONDITIONING X-05/200 | (817)265-1191 | | 128 FAIRVIEW | ARLINGTON, TX 76010 |
PLUM. CONT. | LASITER & LASITER PLUMBING X- | (817)831-4245 | | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING - X | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/31/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
3/12/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/5/2018
| | 3/5/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/20/2017
| | 1/20/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/22/2016
| | 1/22/2016 | |
More Info
|
BACKFLOW | APPROVED |
8/27/2007
| | 8/27/2007 | |
More Info
|
There are currently no reviews on this record.