Permit Info
Short Description:
1 BF FIRE PROT; 5989 AC, 7505 SF, SFR / 2 STORY
Expiration Date:
1/30/2019
Notes:
1 BF FIRE PROT; 5989 AC, 7505 SF, SFR / 2 STORY
10/25/2006 12:00:00 AM
01. ENERGY STAR / GREEN BUILDING.
02. COMPLIANCE WITH THE 2003 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
10. BEAMS=10"W X 28"D.
21. W/12" DIA. PIERS W/(2) #5 REBAR.
26. TEMPERED GLASS REQ'D AT MASTER BATHTUB WINDOW.
29. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
34.TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
37. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
46. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
47. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2003 IRC.
49. INSPECTIONS, TESTING, COMPONENT VERIFICATION AND FINAL HERS SCORE BY THE THIRD PARTY RATER PROVIDING THE REM-RATE REPORT.
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
ONLY CONVENTIAL CEMENT STUCCO IS PERMITTED.
2nd FLOOR: 3-BED ROOMS, 3-BATHS, GAME ROOM AND LARGE ATTIC SPACE.
STAIR LANDINGS ARE REQUIRED. SEE ENCLOSED COPY- R311.5.4
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK PHASE 2A (CFR)
|
BF TESTER | JOSHUA SHIELDS | (972)242-2229 | kencarpenter@verizon.net | 1730 SANFRANCICO ST | CARROLLTON, TX 75007 |
OWNER | DEGRAFF HAROLD | ()- | | | FRISCO, TX 75034-7288 |
MAIL TO | DEGRAFF HAROLD | ()- | | | FRISCO, TX 75034-7288 |
APPLICANT | CITELLI CUSTOM HOMES | (972)668-7798 | | 2975 BELCLAIRE DR. | FRISCO, TX 75034 |
CONTRACTOR | CITELLI CUSTOM HOMES | (972)668-7798 | | 2975 BELCLAIRE DR. | FRISCO, TX 75034 |
ELECT. CTR. | ARI-TEX ELECTRIC INC X- 10/07 | (972)727-9902 | | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
GEN. CONTR. | CITELLI CUSTOM HOMES | (972)668-7798 | | 2975 BELCLAIRE DR. | FRISCO, TX 75034 |
HERS PROVIDE | GUARANTEED WATT SAVER | (405)946-0206 | KELLYPAR@GWSSI.COM | 6444 NW EXPRESSWAY, SUITE 836A | OKLAHOMA CITY, OK 73132 |
MECH. CTR. | BILL JOPLIN'S COMPRESSOR SRVC | (972)569-8339 | | 301 E. MIDWAY STREET | McKINNEY, TX 75069 |
PLUM. CONT. | RIDDELL PLUMBING, INC. X 2/07 | (972)682-4860 | | 242 S HWY 352 | SUNNYVALE, TX 75182 |
STRUCT ENG | CHILDRESS ENGINEERING X-7/07 | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
2/2/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
2/12/2018
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/7/2018
| | 2/7/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/30/2017
| | 1/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/30/2017
| | 1/30/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/7/2016
| | 5/7/2016 | |
More Info
|
BACKFLOW | APPROVED |
1/29/2008
| | 1/29/2008 | |
More Info
|
BACKFLOW | APPROVED |
1/9/2008
| | 1/9/2008 | |
More Info
|
There are currently no reviews on this record.