Permit Info
Short Description:
2295 AC, 3000 SF, SFR / 1 STORY
Notes:
2295 AC, 3000 SF, SFR / 1 STORY
11/12/2009 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
040. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECT LEGEND & ELECT PLAN 1/1000 SQ FT & 1 PER FLOOR MIN.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
053. SEE THE ENCLOSED ONE (1) HOUR FIREWALL DESIGN SKETCH.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(11/12/2009 16:10 JC)
Correct General Notes to current adopted City Of Frisco codes.
Stucco for a single story 100% masonry home is lath with wire mesh and field applied plaster and not cement fiber board.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
CHRISTIE RANCH PH 2A
|
OWNER | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
APPLICANT | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
CONTRACTOR | MERCEDES HOMES | (469)718-7200 | | 11494 LUNA RD #210 | FARMERS BRANCH, TX 75234 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | AIRTRON INC. | (972)272-9633 | cherri.gains@resservices.com | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | MTEEMS@LSPLUMB.COM | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/12/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
There are currently no reviews on this record.