Permit Info
Short Description:
1916 AC, 2519 SF, SFR / 1 STORY
Notes:
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
040. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
053. SEE THE ENCLOSED ONE (1) HOUR FIREWALL DESIGN SKETCH.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Grade Beams : 8" w. x 31" d.
1916 AC, 2519 SF, SFR / 1 STORY
Parcel Info
City/State/Zip:
FRISCO, TX,
|
BF TESTER | PATRICK D RYAN | (972)689-2088 | | NORTH TEXAS LAWN & LANDSCAPE | ROCKWALL, TX 75087 |
OWNER | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
APPLICANT | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
CONTRACTOR | DR HORTON | (214)607-4244 | | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
ELECT. CTR. | DARDEN ELECTRIC | (972)271-5542 | DARDENELECTRIC@MSN.COM | 2326 EXECUTIVE DR | GARLAND, TX 75041 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | ct@nelrod.com | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | CHUCK@RELIANTAC.COM | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | D & M PLUMBING CONTRACTORS | (903)454-3939 | DKEENE5745@AOL.COM | PO BOX 8519 | GREENVILLE, TX 75404 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/12/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
There are currently no reviews on this record.