Permit Info
Short Description:
3942 AC, 5610 SF, SFR / 2 STORY
Notes:
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
3942 AC, 5610 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
COUNTRY CLUB RIDGE AT THE TRAILS PH 2
|
BF TESTER | GABRIEL TAPIA | (972)306-0755 | | 1721 E. FRANKFORD | CARROLLTON, TX 75007 |
OWNER | YOUNTS, JAMES R & WHITNEY S | ()- | DAN@MCHRISTOPHERANDCOMPANY.COM | | FRISCO, TX 75033 |
MAIL TO | HOMEOWNER | ()- | | 11329 NOGALES LN | FRISCO, TX 75033 |
APPLICANT | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
CONTRACTOR | M CHRISTOPHER CUSTOM HOMES | (214)675-9229 | DAN@MCHRISTOPHERANDCOMPANY.COM | 630 OAKMONT CT | FAIRVIEW, TX 75069 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | Stafford, TX 77477 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | CHUCK@RELIANTAC.COM | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
6/9/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
There are currently no reviews on this record.