Permit Info
Short Description:
4001 AC, 4921 SF, SFR / 2 STORY
Notes:
4001 AC, 4921 SF, SFR / 2 STORY
4/19/2010 12:00:00 AM
(4/19/2010 1:58 PM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(4/19/2010 2:01 PM JC)
Porch reqm't. consideration given to this plan design only. All other porch encroachment on other designs, requires the porch to be open on two sides.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034-4577
Subdivision:
PEARSON FARMS 1B
|
BF TESTER | EDWARD GANADRA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | WEEKLEY HOMES - CORPORATE OFFI | (972)939-8787 | | 2286 KING ARTHUR BLVD | LEWISVILLE, TX 75056 |
APPLICANT | WEEKLEY HOMES - CORPORATE OFFI | (972)939-8787 | | 2286 KING ARTHUR BLVD | LEWISVILLE, TX 75056 |
CONTRACTOR | WEEKLEY HOMES - CORPORATE OFFI | (972)939-8787 | | 2286 KING ARTHUR BLVD | LEWISVILLE, TX 75056 |
ELECT. CTR. | IES RESIDENTIAL, INC | (281)498-2212 | BRITT.CRIST@IES-CO.COM | 10203 MULA CIRCLE | Stafford, TX 77477 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | MDOUGLAS@ADVENTAIR.COM | 500 S. KEALY | LEWISVILLE, TX 75057 |
PLUM. CONT. | LASITER & LASITER PLUMBING | (817)831-4245 | SHANNONB@LASITER.COM | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | ERIC L. DAVIS ENGINEERING, INC | (972)564-0592 | ERICDAVIS@ELDENGINEERING.COM | P.O. BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/9/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
There are currently no reviews on this record.