Permit Info
Short Description:
4117 AC, 5330 SF, SFR / 2 STORY
Notes:
4117 AC, 5330 SF, SFR / 2 STORY
5/14/2010 12:00:00 AM
(5/14/2010 3:45 PM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(5/14/2010 3:45 PM JC)
Grade Beams : 10" w. x 20" d. (MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGES OF STONELAKE ESTATES #1C (CFR)
|
BF TESTER | EDWARD GANADRA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
APPLICANT | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
CONTRACTOR | K HOVNANIAN HOMES | (469)737-1400 | | 5808 W. PLANO PKWY | PLANO, TX 75093 |
ELECT. CTR. | CUMMINGS ELECTRICAL, INC | (817)355-5300 | CMONTGOMERY@CUMMINGSELEC.COM | 14900 GRAND RIVER RD STE 124 | FORT WORTH, TX 76155 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/31/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/30/2010
| | 8/30/2010 | |
More Info
|
There are currently no reviews on this record.