Permit Info
Short Description:
3785 AC, 4615 SF, SFR / 2 STORY
Approved Date:
10/21/2010
Notes:
3785 AC, 4615 SF, SFR / 2 STORY
5/4/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
007. BEAMS=8"W X 30"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CYPRESS CREEK #1 (CFR)
|
BF TESTER | HAYDON M FURR | (214)585-6406 | | 7101 VIRGINIA PKWY APT 521 | MC KINNEY, TX 75071 |
OWNER | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
APPLICANT | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
CONTRACTOR | DREES CUSTOM HOMES | (972)953-4500 | PLEWIS@DREESHOMES.COM | 6225 SH 161 STE #400 | IRVING, TX 75038 |
ELECT. CTR. | FOX ELECTRIC | (817)461-2571 | RESIDENTALSERVICE@FOXELECTRIC.COM | PO BOX 13338 | ARLINGTON, TX 76094 |
HERS PROVIDE | EIC, INC./COMFORT HOME | (972)485-4722 | CSIMPSON@COMFORTHOME.COM | 102 N. SHILOH ROAD #310 | GARLAND, TX 75042 |
MECH. CTR. | FRYMIRE ENGINEERING | (972)620-3500 | | 2818 SATSUMA | DALLAS, TX 75226 |
PLUM. CONT. | LASITER & LASITER PLUMBING | (817)831-4245 | SHANNONB@LASITER.COM | P.O. BOX 14638 | HALTOM CITY, TX 76117 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
10/25/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/21/2010
| | 10/21/2010 | |
More Info
|
There are currently no reviews on this record.