Permit Info
Short Description:
4393 AC, 5228 SF, SFR / 2 STORY
Approved Date:
12/14/2010
Notes:
4393 AC, 5228 SF, SFR / 2 STORY
8/23/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
020. W/12" DIA. PIERS W/(1) #5 REBAR.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONE CREEK VILLAGE PH 2
|
BF TESTER | KENNETH COOPER | (972)923-0711 | | 2013 BRIARGATE LANE | MESQUITE, TX 75181 |
OWNER | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | JOE@ENTERPRISE.COM | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
12/14/2010
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
12/14/2010
| | 12/14/2010 | |
More Info
|
There are currently no reviews on this record.