Permit Info
Short Description:
1 BF FIRE PROT - 5249 AC, 6486 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
1/24/2018
Notes:
1 BF FIRE PROT - 5249 AC, 6486 SF, SFR / 2 STORY
10/21/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
010. BEAMS=10"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2nd FLOOR: 3-BED ROOMS, 2-BATHS, GAME ROOM WITH A WET BAR, CARD ROOM, RETREAT & MEDIA ROOM
(11/11/2010 11:15 AM VI)
This review to add the Retreat room on the 2nd floor.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONE CREEK VILLAGE PH 2
|
BF TESTER | CHRISTOPHER COFFMAN | (972)723-5535 | SALES@ALLIEDFLOW.COM | PO BOX 1150 | MIDLOTHIAN, TX 76065 |
OWNER | WRIGHT, RODNEY R & LESLIE A | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
MAIL TO | WRIGHT, RODNEY R & LESLIE A | ()- | LORI@SHADDOCKHOMES.COM | | FRISCO, TX 75034 |
APPLICANT | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES, LTD | (469)241-9581 | LORI@SHADDOCKHOMES.COM | 2400 DALLAS PKWY, STE 560 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | | 1500 MARTINEZ LANE | WYLIE, TX 75098 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | THE NELROD COMPANY | (817)546-0160 | CT@NELROD.COM | 3109 LUBBOCK AVE. | FORT WORTH, TX 76109 |
MECH. CTR. | KRUGER & SON HEATING & AIR | (972)271-9319 | | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM - ADRIA | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/30/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
3/3/2011
|
BACK FLOW FORM REVIEW |
$25.00
|
2/3/2016
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/24/2017
| | 1/24/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/25/2016
| | 1/25/2016 | |
More Info
|
BACKFLOW | APPROVED |
2/28/2011
| | 2/28/2011 | |
More Info
|
BACKFLOW | APPROVED |
2/25/2011
| | 2/25/2011 | |
More Info
|
There are currently no reviews on this record.