Permit Info
Short Description:
SEE BF09-0041 - Frisco Square Townhomes
Expiration Date:
1/31/2014
Notes:
SEE BF09-0041 - Frisco Square Townhomes
2/2/2006 12:00:00 AM
01. ***ENERGY STAR***
02. COMPLIANCE WITH THE APRIL 2003 CONTRACTOR GUIDELINE REQ'D
03. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS
10. BEAMS=10"W X 28"D-ALL INTERIOR BEAMS.
13. BEAMS=10"W X 32"D-ALL PERIMETER BEAMS.
41. TWO-HOUR FIRE SEPERATION REQUIRED.
43. SEE SOUND TRANSMISSION CODE COMPLIANCE DATA SHEET ATTACHED.
49. SAME 3RD PARTY RATER MUST DO ALL INSPECTIONS & TESTING OF SUPPLY AND EXHAUST DUCT(S) AND DAMPERS TO MEET ENERGY STAR/GREEN BLDG REQUIREMENTS..
50. CSST GAS PIPING ALLOWED - SEE INFO SKETCH IN LOBBY AND (OR) ORDINANCE(S) 03-07-58 & 03-07-59.
54. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
57. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
ONLY CONVENTIONAL STUCCO IS PERMITTED FOR RESIDENTIAL CONSTRUCTION IN FRISCO.
FRISCO RECOMMENDS A CONCRETE 2" STEM-WALL SEPERATION TO PREVENT FLOODING BETWEEN UNITS.
FIREPLACE VENTS AND ALL OTHERS MUST PENETRATE THE ROOF AT LEAST 5 FEET FROM A "0" LOT LINE.
THE FIRE RATED WALL MUST EXTEND TO THE FRONT AND REAR ON THE "O" LINE OF THE ADJOINING UNIT.
WE RECOMMEND A FLOOR DRAIN FOR A 3rd FLOOR UTILITY
ROOM.
Parcel Info
Subdivision:
FRISCO SQUARE #05
|
BF TESTER | JAMES GREEN | (972)840-1700 | | 412 MAGNOLIA DR | FORNEY, TX 75126 |
OWNER | DETTER JON G & SANDRA R | ()- | | | FRISCO, TX 75034-4939 |
MAIL TO | ALVIN SUTHERLAND | (412)335-6457 | | 8341 MOORE ST | FRISCO, TX 75034-4939 |
APPLICANT | QUANTUM CUSTOM HOMES X-7/05 | (972)401-1333 | | 820 S. MCARTHUR # 105 | COPPELL, TX 75019 |
CONTRACTOR | QUANTUM CUSTOM HOMES X-7/05 | (972)401-1333 | | 820 S. MCARTHUR # 105 | COPPELL, TX 75019 |
ELECT. CTR. | FOX ELECTRIC X-1/07 | (817)461-2591 | | 1104 COLORADO LN | ARLINGTON, TX 76015 |
GEN. CONTR. | QUANTUM CUSTOM HOMES X-7/05 | (972)401-1333 | | 820 S. MCARTHUR # 105 | COPPELL, TX 75019 |
HERS PROVIDE | EIC, INC./COMFORT HOME X-03/2 | (972)485-4722 | CSIMPSON@COMFORTHOME.COM | 102 N. SHILOH ROAD #310 | GARLAND, TX 75042 |
MECH. CTR. | NORTHSIDE A/C X-05/06 | (214)315-0518 | | P.O. BOX 270658 | FLOWER MOUND, TX 75027 |
PLUM. CONT. | FRITZ PLUMBING (PLUM) X-1/07 | (972)335-3560 | | P.O. BOX 194 | FRISCO, TX 75034 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING - X | (972)620-8204 | tami@strandsystems.com | 2964 LBJ FREEWAY # 312 | DALLAS, TX 75234 |
|
BACK FLOW FORM REVIEW |
$25.00
|
3/11/2011
|
BACK FLOW FORM REVIEW |
$25.00
|
2/10/2012
|
BACK FLOW FORM REVIEW |
$25.00
|
3/12/2013
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/12/2013
| | 3/12/2013 | |
More Info
|
BACKFLOW | APPROVED |
1/31/2012
| | 1/31/2012 | |
More Info
|
BACKFLOW | APPROVED |
2/21/2011
| | 2/21/2011 | |
More Info
|
There are currently no reviews on this record.