Permit Info
Short Description:
4237 AC, 5265 SF, SFR / 2 STORY
Notes:
4237 AC, 5265 SF, SFR / 2 STORY
11/12/2010 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
016. BEAMS=12"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
2nd FLOOR: 4-BED ROOMS, 2-BATHS, GAME & MEDIA ROOM WITH A WET BAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
COUNTRY CLUB RIDGE AT THE TRAILS PH 1
|
OWNER | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
APPLICANT | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
CONTRACTOR | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
ELECT. CTR. | PUCKETT ELECTRIC | (972)864-0020 | PUCKETTELEC@YAHOO.COM | 2602 INDUSTRIAL LANE | GARLAND, TX 75041 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS | (817)379-0866 | BKRAMM@NORTEXFOUNDATION.COM | 845 A ENTERPRISE PLACE | ROANOKE, TX 76262 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/19/2011
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/24/2011
| | 3/24/2011 | |
More Info
|
There are currently no reviews on this record.