Permit Info
Short Description:
1 BF FIRE PROT - 5085 AC, 6367 SF, SFR / 2 STORY
Notes:
1 BF FIRE PROT - 5085 AC, 6367 SF, SFR / 2 STORY
2/10/2011 12:00:00 AM
(2/10/2011 2:50 PM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
016. BEAMS=12"W X 26"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(2/10/2011 2:52 PM JC)
Driveway gate must be at (or) behind the 30' front yard set-back line. No encroachment allowed.
(6/14/2017 1:09 PM BJS)
NO FIRE PROT SYSTEM PER BILLY SANDLIN 6-14-17
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
COUNTRY CLUB RIDGE AT THE TRAILS PH 2
|
BF TESTER | PATRICK RYAN | (972)689-2088 | | NORTH TEXAS LAWN & LANDSCAPE | ROCKWALL, TX 75087 |
OWNER | WILSON, JASON D & NANCY A | ()- | jbgiddens@gmail.com | | FRISCO, TX 75033 |
MAIL TO | WILSON, JASON D & NANCY A | ()- | jbgiddens@gmail.com | | FRISCO, TX 75033 |
APPLICANT | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
CONTRACTOR | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
ELECT. CTR. | PUCKETT ELECTRIC | (972)864-0020 | PUCKETTELEC@YAHOO.COM | 2602 INDUSTRIAL LANE | GARLAND, TX 75041 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS | (817)379-0866 | info@nortexfoundation.com | 4416 KELLER HICKS RD | FORT WORTH, TX 76244 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
8/24/2011
| | 8/24/2011 | |
More Info
|
There are currently no reviews on this record.