Permit Info
Short Description:
4180 AC, 4937 SF, SFR / 2 STORY
Notes:
4180 AC, 4937 SF, SFR / 2 STORY
3/31/2011 12:00:00 AM
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
016. BEAMS=12"W X 26"D.
023. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
051. WINDOW BOX-OUTS MUST NOT EXCEED TWICE THE WINDOW M.O. AREA.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2ND FLOOR: 3BR, 2BA, LOFT, GAME, MEDIA, BALCONY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
MEADOW CREEK PH II
|
BF TESTER | PATRICK RYAN | (972)689-2088 | | NORTH TEXAS LAWN & LANDSCAPE | ROCKWALL, TX 75087 |
OWNER | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
APPLICANT | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
CONTRACTOR | SUMEER HOMES | (972)659-0655 | jbgiddens@gmail.com | 2404 TEXAS DRIVE #103 | IRVING, TX 75062 |
ELECT. CTR. | PUCKETT ELECTRIC | (972)864-0020 | PUCKETTELEC@YAHOO.COM | 2602 INDUSTRIAL LANE | GARLAND, TX 75041 |
HERS PROVIDE | METRO CODE ANALYSIS | (817)335-1497 | INFORMATION@METROCODE.COM | 2630 W FREEWAY, SUITE 200 | FT WORTH, TX 76102 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | PROFESSIONAL PLUMBERS GROUP IN | (972)429-5575 | GCOKER@PLUMBERSGROUP.COM | 1322 CENTURY WAY | WYLIE, TX 75098 |
STRUCT ENG | NORTEX FOUNDATION DESIGNS | (817)379-0866 | info@nortexfoundation.com | 4416 KELLER HICKS RD | FORT WORTH, TX 76244 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/14/2011
| | 9/14/2011 | |
More Info
|
There are currently no reviews on this record.