Permit Info
Short Description:
2100 AC, 2766 SF, SFR / 2 STORY
Notes:
2100 AC, 2766 SF, SFR / 2 STORY
5/16/2011 12:00:00 AM
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. BEAMS=8"W X 28"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
040. ON "0" SET-BACK SIDE OF HOUSE NO METERS OR VENTS ARE ALLOWED. GUTTER DOWNSPOUTS MUST DISCHARGE ONTO SAME PROPERTY 5'-0" FROM FOUNDATION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
053. SEE THE ENCLOSED ONE (1) HOUR FIREWALL DESIGN SKETCH.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
(5/16/2011 8:54 AM JC)
2nd. story with (2) bedrooms, (1) bath & gm. rm.
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
SEDONA #2 (CFR)
|
OWNER | DR HORTON | (214)607-4244 | shmayraz@drhorton.com | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
APPLICANT | DR HORTON | (214)607-4244 | shmayraz@drhorton.com | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
CONTRACTOR | DR HORTON | (214)607-4244 | shmayraz@drhorton.com | 1901 ASCENSION BLVD.,#100 | ARLINGTON, TX 76006 |
ELECT. CTR. | DARDEN ELECTRIC | (972)271-5542 | DARDENELECTRIC@MSN.COM | 2326 EXECUTIVE DR | GARLAND, TX 75041 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | BRENT@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)831-3950 | dripley@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | D & M PLUMBING CONTRACTORS | (903)454-3939 | DKEENE5745@AOL.COM | PO BOX 8519 | GREENVILLE, TX 75404 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/20/2011
| | 9/20/2011 | |
More Info
|
There are currently no reviews on this record.