Permit Info
Short Description:
4081 AC, 5060 SF, SFR / 2 STORY
Notes:
4081 AC, 5060 SF, SFR / 2 STORY
6/9/2011 12:00:00 AM
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
NOTICE: THE AREAS SHOWN AS SIDING ON THE SECOND FLOOR ARE NOT APPROVED. THESE AREAS MUST BE CEMENT FIBER OR IF SIDING MUST BE CANTILEAVERED 4'' TO 6" OR CEMENT STUCCO.
2nd FLOOR:3-BED ROOMS, 2 1/2 BATHS, GAME & MEDIA ROOM WITH A WET BAR.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
VILLAGE AT PANTHER CREEK #1 THE (CFR)
|
BF TESTER | ROBERT HARVEY | (972)346-3999 | | 3793 PHEASANT RUN | CELINA, TX 75009 |
OWNER | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
APPLICANT | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
CONTRACTOR | DARLING HOMES | (972)624-4100 | msibigtroth@darlinghomes.com | 2500 LEGACY STE # 100 | FRISCO, TX 75034 |
ELECT. CTR. | IN CHARGE ELCTRICAL SERVICES L | (512)778-6240 | SETHROBINSON@IN-CHARGE-ELECTIC.COM | 3101 US HWY 183 | LIBERTY HILL, TX 78642 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
MECH. CTR. | TEMPO MECHANICAL SERVICES | (972)579-2000 | RENEE.TURK@TEMPOAIR.COM | 2611 E PIONEER DR | IRVING, TX 75061 |
PLUM. CONT. | FRITZ PLUMBING | (972)335-3560 | THOMAS@FRITZPLUMBING.COM | 11109 FRISCO STREET | FRISCO, TX 75034 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/3/2011
| | 10/3/2011 | |
More Info
|