Permit Info
Short Description:
1 BF FIRE PROT. 7445 AC, 9154 SF, SFR / 2 STORY
Expiration Date:
10/26/2018
Notes:
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
021. W/12" DIA. PIERS W/(2) #5 REBAR.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
027. TEMPERED GLASS REQ'D AT STAIR LANDING WINDOW(S).
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Certificate of elevation req'd. with ref. to the flood plain elev. prior to request for final inspection.
(10/1/2010 10:38 AM JC)
Permit re-issued for increased 2nd. story area and other plan changes.
1 BF FIRE PROT. 7445 AC, 9154 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONEBRIAR CREEK (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | MARTZ STEVE & | ()- | TRIORDAN@BALKMAN-RIORDANHOMES.COM | ROMY MARTZ | FRISCO, TX 75034-5934 |
MAIL TO | MARTZ STEVE & ROMY MARTZ | ()- | | 11 CLIFF TRL | FRISCO, TX 75034 |
APPLICANT | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | TRIORDAN@BALKMAN-RIORDANHOMES.COM | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
CONTRACTOR | BALKMAN - RIORDAN CUSTOM HOMES | (972)403-9298 | TRIORDAN@BALKMAN-RIORDANHOMES.COM | 5804 COMMUNICATION, SUITE 100 | PLANO, TX 75093 |
ELECT. CTR. | ARI-TEX ELECTRIC INC | (972)727-9902 | SERVICECARI-TEX.COM | 606 CENTRAL EXPRESSWAY | ALLEN, TX 75013 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | GUARANTEED WATT SAVER | (405)946-0206 | KELLYPAR@GWSSI.COM | 6444 NW EXPRESSWAY, SUITE 836A | OKLAHOMA CITY, OK 73132 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | aseutter@chapmanair&heat.com | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RELIABLE PLUMBING | (972)285-0939 | REPLUG@AIRMAIL.NET | 2509 FRANKLIN | MESQUITE, TX 75150 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | tchildress@cesglobal.com | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
8/7/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
10/27/2011
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
7/14/2017
| | 7/14/2017 | |
More Info
|
BACKFLOW | APPROVED |
10/26/2011
| | 10/26/2011 | |
More Info
|
There are currently no reviews on this record.