Permit Info
Short Description:
3608 AC, 4435 SF, SFR / 2 STORY
Notes:
3608 AC, 4435 SF, SFR / 2 STORY
5/26/2011 12:00:00 AM
(5/26/2011 2:47 PM JC)
001. ENERGY STAR/GREEN BLDG/90 DAY DIRECTIVE EFF 04/01/2011.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(5/26/2011 2:48 PM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
CROWN RIDGE #2 (CFR)
|
BF TESTER | EDWARD GANDARA | (972)671-3776 | | 3901 CLIFTON | RICHARDSON, TX 75082 |
OWNER | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
APPLICANT | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
CONTRACTOR | K HOVNANIAN HOMES | (469)737-1400 | bdavidson@khov.com | 5808 W. PLANO PKWY | PLANO, TX 75093 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | SCHASE@SWARTZ-ELECTRIC-INC.COM | 228 IRBY LANE | IRVING, TX 75061 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | 900 ALPHA #430 | RICHARDSON, TX 75081 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
10/31/2011
| | 10/31/2011 | |
More Info
|
There are currently no reviews on this record.