Permit Info
Short Description:
2765 AC, 3195 SF, SFR / 1 STORY
Notes:
2765 AC, 3195 SF, SFR / 1 STORY
8/2/2011 12:00:00 AM
(8/2/2011 11:18 AM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
023. GARAGE MUST BE A MIN. 18'W X 20'D CLEAR SHEET ROCK TO SHEET ROCK.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
030. 1ST FLOOR WINDOW BOX-OUTS MUST HAVE MASONRY BELOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
(8/2/2011 11:18 AM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX,
Subdivision:
VILLAGE LAKES PH 2B
|
BF TESTER | KODIE LOERA | (214)392-2406 | | 510 PEAR DR | ROCKWALL, TX 75087 |
OWNER | MERITAGE HOMES | (972)580-6300 | Michelle.Rae@meritagehomes.com | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
APPLICANT | MERITAGE HOMES | (972)580-6300 | Michelle.Rae@meritagehomes.com | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
CONTRACTOR | MERITAGE HOMES | (972)580-6300 | Michelle.Rae@meritagehomes.com | 909 HIDDEN RIDGE #400 | IRVING, TX 75038 |
ELECT. CTR. | SWARTZ ELECTRIC | (972)254-3480 | SCHASE@SWARTZ-ELECTRIC-INC.COM | 228 IRBY LANE | IRVING, TX 75061 |
HERS PROVIDE | BURGESS CONSTRUCTION CONSULTAN | (214)291-3141 | CBROOKS@BURGESS-INC.COM | 1255 W 15TH STE 100 | PLANO, TX 75075 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/11/2011
| | 11/11/2011 | |
More Info
|
There are currently no reviews on this record.