Permit Info
Short Description:
1 BF FIRE PROT - 4814 AC, 6387 SF, SFR / 2 STORY
Expiration Date:
1/24/2019
Notes:
1 BF FIRE PROT - 4814 AC, 6387 SF, SFR / 2 STORY
7/8/2011 12:00:00 AM
(7/8/2011 3:47 PM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(7/8/2011 3:48 PM JC)
2nd. story w/ (2) bedrooms, (2) baths, game room & non-AC attic storage.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
THE SHORES AT WATERSTONE PH 1
|
BF TESTER | DANIEL CANTU | (214)554-3105 | Cantufire@gmail.com | 1605 E PARK | PLANO, TX 75074 |
OWNER | FERGUSON, DANIEL & ELISABETH | ()- | CFARRELL@SKORBURGCOMPANY.COM | | FRISCO, TX 75034 |
MAIL TO | FERGUSON, DANIEL & ELISABETH | ()- | CFARRELL@SKORBURGCOMPANY.COM | | FRISCO, TX 75034 |
APPLICANT | WINDSOR HOMES CUMBERLAND LLC | (214)522-4945 | CFARRELL@SKORBURGCOMPANY.COM | 3838 OAK LAWN AVENUE #1212 | DALLAS, TX 75219 |
CONTRACTOR | WINDSOR HOMES CUMBERLAND LLC | (214)522-4945 | CFARRELL@SKORBURGCOMPANY.COM | 3838 OAK LAWN AVENUE #1212 | DALLAS, TX 75219 |
ELECT. CTR. | C & B ELECTRIC | (972)790-0707 | | 225 GILBERT CIRCLE | GRAND PRAIRIE, TX 75050 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | RFROST@GSFIREPORTECTIONLLC.COM | 906 W MCDERMOTT #116 | ALLEN, TX |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | BRENT@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
MECH. CTR. | ADVENT AIR CONDITIONING, INC | (972)221-4373 | mlewis@adventair.com | 500 S. KEALY | LEWISVILLE, TX 75057 |
PLUM. CONT. | L & S PLUMBING | (972)331-6850 | chernandez@lsplumb.com | 707 E ARAPAHO RD STE 210 | RICHARDSON, 75081 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | 100 N. CENTRAL EXPRESSWAY STE. | DALLAS, TX 75201 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/27/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
1/18/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
11/14/2011
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
1/11/2018
| | 1/11/2018 | |
More Info
|
BACKFLOW | APPROVED |
1/24/2017
| | 1/24/2017 | |
More Info
|
BACKFLOW | APPROVED |
1/27/2016
| | 1/27/2016 | |
More Info
|
BACKFLOW | APPROVED |
11/4/2011
| | 11/4/2011 | |
More Info
|
There are currently no reviews on this record.