Short Description:
3213 AC, 3883 SF, SFR / 2 STORY
Notes:
3213 AC, 3883 SF, SFR / 2 STORY
7/14/2011 12:00:00 AM
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
006. BEAMS=8"W X 28"D.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
038. RETAINING WALLS TWO (2) FT OR TALLER MUST BE OF ENGINEERED DESIGN.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
060. ONLY THE EOR STRUCTURE FRAME AND DETAILS ARE INCLUDED AS PART OF TIHS ISSUED BUILDING PERMIT.
2ND FLOOR: 1BA, MEDIA, LOFT, WETBAR
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
DOMINION AT PANTHER CREEK #4A (CFR)
|
BF TESTER | JAY S. BIRD JR | (972)647-8398 | | 1433 CHISUM TRAIL | WHITESBORO, TX 76273 |
OWNER | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #6001544 DA | ADDISON, TX 75001 |
APPLICANT | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #6001544 DA | ADDISON, TX 75001 |
CONTRACTOR | GRAND HOMES | (972)387-6037 | LDYE@GRANDHOMES.COM | 15950 N DALLAS PKY #6001544 DA | ADDISON, TX 75001 |
ELECT. CTR. | IES RESIDENTIAL, INC | (972)562-7724 | BECKY.COLLIER@IES-CO.COM | 713 TOWER LANE SUITE A | MCKINNEY, TX 75069 |
HERS PROVIDE | ACP ALLIED CONSTRUCTION PROFES | (214)227-9540 | TONYA@ENERGYACP.COM | 1900 ESPINOSA DRIVE | CARROLLTON, TX 75010 |
MECH. CTR. | AIRTRON INC | (972)272-9633 | CHERRI.GAINS@RESSERVICES.COM | 9525 FORESTVIEW STREET | DALLAS, TX 75243 |
PLUM. CONT. | TEXAS UNITED PLUMBING | (972)446-2500 | | 1451 HALSEY WAY | CARROLLTON, TX 75007 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | TAMI@STRANDSYSTEMS.COM | 6221 RIVERSIDE DRIVE #116 | IRVING, TX 75039 |
Total Fees |
Charged: $0.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
11/14/2011
| | 11/14/2011 | |
More Info
|