Permit Info
Short Description:
1 BF FIRE PROT-- 5957 AC, 7328 SF, SFR / 2 STORY
Expiration Date:
4/19/2019
Notes:
(3/11/2011 1:02 PM JC)
001. ENERGY STAR / GREEN BUILDING.
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
004. BEAMS=8"W X 24"D.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
043. COMPLIANCE WITH E.O.R. FOUNDATION DESIGN NOTE(S) REQ'D. BY BUILDER PRIOR TO THE START OF CONSTRUCTION. COPY SAME TO THE CITY OF FRISCO.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
055. FUEL BURNING APPLIANCE INSTALLATION MUST BE CODE COMPLIANT.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(3/11/2011 1:02 PM JC)
(FWF)
1 BF FIRE PROT-- 5957 AC, 7328 SF, SFR / 2 STORY
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | THOMAS J STEHLIK | (214)350-1755 | | 1431 STONY VALLEY DR | PONDER, TX 76259-5008 |
OWNER | CHIANG MICHAEL C & WENDY | ()- | BB@BOBBOBBITTHOMES.COM | | FRISCO, TX 75034-5886 |
MAIL TO | CHIANG MICHAEL C & WENDY | ()- | BB@BOBBOBBITTHOMES.COM | | FRISCO, TX 75034-5886 |
APPLICANT | BOB BOBBITT CO, INC. | (214)618-9729 | BB@BOBBOBBITTHOMES.COM | 8000 WARREN PKWY #204 | Frisco, Tx 75034 |
CONTRACTOR | BOB BOBBITT CO, INC. | (214)618-9729 | BB@BOBBOBBITTHOMES.COM | 8000 WARREN PKWY #204 | Frisco, Tx 75034 |
ELECT. CTR. | POTTER ELECTRIC | (972)442-1600 | | 709 HWY 78 SOUTH | FARMERSVILLE, TX 75442 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | ENERGY RATED HOMES | (972)504-6800 | STAN@IHSTEXAS.COM | 651 WILLOWVIEW DR | PROSPER, TX 75078 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | ascutter@chapmanair.com | 10750 SANDHILL | DALLAS, TX 75238 |
PLUM. CONT. | RIDDELL PLUMBING, INC. | (972)682-4860 | SCOTT@RIDDELLPLUMBING.COM | 3700 US HIGHWAY 80 EAST | MESQUITE, TX 75149 |
STRUCT ENG | LARRY SMITH ENGINEERING | (972)964-2161 | ARSMITH@LARRYSMITHENG.COM | 2115 TEAKWOOD LANE SUITE 450 | PLANO, TX 75075 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/16/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
4/24/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
11/17/2011
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/2/2018
| | 5/17/2018 | |
More Info
|
BACKFLOW | APPROVED |
4/19/2017
| | 4/19/2017 | |
More Info
|
BACKFLOW | APPROVED |
4/19/2016
| | 4/19/2016 | |
More Info
|
BACKFLOW | APPROVED |
11/14/2011
| | 11/14/2011 | |
More Info
|
There are currently no reviews on this record.