1 BF FIRE PROT - 5830 AC, 7435 SF, SFR / 2 STORY
8/3/2011 12:00:00 AM
(8/3/2011 10:24 AM JC)
002. COMPLIANCE WITH THE 2006 CODES, AMENDMENTS, ORDINANCES & SUBDIVISION REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
024. EXITWAYS (HALLWAYS) MUST BE A MIN. 36"W INCLUDING ARCHED OR CASED OPENINGS. (TWO OR MORE ROOMS)
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
026. TEMPERED GLASS REQ'D AT ALL BATHROOM HAZARD LOCATIONS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
037. DRIVEWAY SLOPE MUST NOT EXCEED 12% - PLOT PLANS W/GRADES REQUIRED.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS A DRAWING AND SPECIFICATION OF THE REQUIRED BARRIER-FREE RAMP.
(8/3/2011 10:24 AM JC)
(MFD)
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | THOMAS STEHLIK | (214)350-1755 | TJSTEHLIK@HOTMAIL.COM | PO BOX 630886 | IRVING, TX 75063 |
OWNER | LAWRENCE ANDREW & JENNIFER | ()- | | | FRISCO, TX 75034-7286 |
MAIL TO | LAWRENCE ANDREW & JENNIFER | ()- | | | FRISCO, TX 75034-7286 |
APPLICANT | KELLY CUSTOM HOMES | (214)537-0371 | | P.O. BOX 262109 | PLANO, TX 75026 |
CONTRACTOR | KELLY CUSTOM HOMES | (214)537-0371 | | P.O. BOX 262109 | PLANO, TX 75026 |
ELECT. CTR. | PUCKETT ELECTRIC | (972)864-0020 | PUCKETTELEC@YAHOO.COM | 2602 INDUSTRIAL LANE | GARLAND, TX 75041 |
FIRE CONTACT | Rescom Fire Systems | (214)538-7500 | | PO Box 630806 | Irving, TX 75063 |
HERS PROVIDE | FOX ENERGY SPECIALIST | (817)922-9000 | DLYONS@FOX-ENERGY.COM | 3109 LUBBOCK AVENUE | FORT WORTH, TX 76109 |
INSTALLER | AIR MECHANIX, LLC | (214)394-5520 | DALE.CONNER@YAHOO.COM | | PLANO, TX 75093 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | 2166 S JUPITER | GARLAND, TX 75041 |
PLUM. CONT. | RELIABLE PLUMBING | (972)285-0939 | REPLUG@AIRMAIL.NET | 2509 FRANKLIN | MESQUITE, TX 75150 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/5/2012
|
Total Fees |
Charged: $25.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
9/10/2016
| | 9/10/2016 | |
More Info
|
BACKFLOW | APPROVED |
4/5/2012
| | 4/5/2012 | |
More Info
|