Permit Info
Short Description:
1 BF FIRE PROT -8683 AC, 12433 SF, SFR / 1 STORY
Expiration Date:
3/7/2019
Notes:
1 BF FIRE PROT -8683 AC, 12433 SF, SFR / 1 STORY
5/21/2012 12:00:00 AM
001. COMPLIANCE WITH THE APRIL 5, 2011 ZONING ORDINANCE REQUIRED.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
032. SECOND FLOOR SIDING AREA MUST NOT EXCEED 50% OF THE TOTAL NET EXPOSED WALL AREA.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(5/21/2012 9:58 AM JC)
Grade Beams : 10" x 36" house, 1O" x 32" garage.
12" dia. piers with vert. rebar per plan sch'l.
House permitted as single story with a detached garage and second story living quarter. Further modification to the main structure( second story) by building permit only.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
STONEBRIAR CREEK (CFR)
|
BF TESTER | KYLE MIHALOVICH | (817)379-0856 | service@alltestbackflow.com | 600 HENRIETTA CREEK RD. | ROANOKE, TX 76262 |
OWNER | PRIEST CHARLES E | ()- | | | FRISCO, TX 75034-5934 |
MAIL TO | PRIEST CHARLES E | ()- | | | FRISCO, TX 75034-5934 |
APPLICANT | ROBERT J SKINNER JR LLC | (972)839-7748 | ROBERTSKINNERLLC@PRODIGY.NET | | DALLAS, TX 75205 |
CONTRACTOR | ROBERT J SKINNER JR LLC | (972)839-7748 | ROBERTSKINNERLLC@PRODIGY.NET | | DALLAS, TX 75205 |
ELECT. CTR. | HOLDER & HOLDER ELECTRIC INC | (972)424-6214 | EMMETTHOLDER@HOTMAIL.COM | | PLANO, TX 75074 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | ECS, INC | (940)240-1033 | | PO BOX 1256 | ARGYLE, TX 76226 |
MECH. CTR. | NORTHSIDE A/C | (972)318-5097 | popebobby@verizon.net | | FLOWER MOUND, TX 75027 |
PLUM. CONT. | BARROW PLUMBING CO | (972)562-5404 | jsbarrow@att.net | RECEIVED APPLICATION | MCKINNEY, TX 75071 |
STRUCT ENG | STRAND SYSTEMS ENGINEERING | (972)620-8204 | jennifer@strandsystems.com | | IRVING, TX 75039 |
|
BACK FLOW FORM REVIEW |
$25.00
|
3/14/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
6/16/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
4/10/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
3/7/2016
|
BACK FLOW FORM REVIEW |
$25.00
|
3/20/2013
|
Total Fees |
Charged: $125.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
3/27/2018
| | 3/27/2018 | |
More Info
|
BACKFLOW | APPROVED |
6/2/2017
| | 6/2/2017 | |
More Info
|
BACKFLOW | APPROVED |
3/7/2016
| | 3/7/2016 | |
More Info
|
BACKFLOW | BF FAILED |
2/22/2016
| | 2/22/2016 | |
More Info
|
BACKFLOW | APPROVED |
3/19/2013
| | 3/19/2013 | |
More Info
|
There are currently no reviews on this record.