Permit Info
Short Description:
1 BF FIRE PROT - 4795 AC, 6111 SF, SFR / 2 STORY
Status:
RES LETTER FINAL SENT
Expiration Date:
2/3/2018
Notes:
1 BF FIRE PROT - 4795 AC, 6111 SF, SFR / 2 STORY
5/3/2013 12:00:00 AM
(5/3/2013 8:24 AM JC)
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
012. BEAMS=10"W X 30"D.
020. W/12" DIA. PIERS W/(1) #5 REBAR.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
034. SIDING & TRIM MUST BE CEMENT FIBER OR ENGINEERED TREATED WOOD PRODUCT.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
036. MINIMUM OF 24" ON SILL HEIGHT AT 2ND STORY OPERABLE WINDOWS.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
047. RISERS MUST BE 7 3/4" MAXIMUM; TREAD MINIMUM OF 10". LANDING AS REQUIRED BY 2006 IRC.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
(5/3/2013 8:25 AM JC)
2nd. story w/ (3) bedrooms, (3) baths & game room.
Parcel Info
City/State/Zip:
FRISCO, TX, 75034
Subdivision:
CHAPEL CREEK #2A (CFR)
|
BF TESTER | BRIAN HAUBERG | (469)939-1948 | 1BACKFLOW@GMAIL.COM | 2513 BRIARWOOD | PLANO, TX 75074 |
OWNER | HALLMAN SAMUEL J & | ()- | bkearley5@verizon.net | JUDY C HALLMAN | FRISCO, TX 75034-1872 |
MAIL TO | HALLMAN SAMUEL J & JUDY C HALL | ()- | bkearley5@verizon.net | | FRISCO, TX 75034 |
APPLICANT | LEWIS & EARLY CUSTOM HOMES | (214)682-7171 | bkearley5@verizon.net | | ARGYLE, TX 76226 |
CONTRACTOR | LEWIS & EARLY CUSTOM HOMES | (214)682-7171 | bkearley5@verizon.net | | ARGYLE, TX 76226 |
ELECT. CTR. | ODYSSEY ELECTRIC LLC | (817)269-2750 | TLF122@YAHOO.COM | | NORTH RICHLAND HILLS, TX 76182 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | ()- | | 906 W MCDERMOTT #116 | ALLEN, TX |
HERS PROVIDE | ERIC L DAVIS ENGINEERING | (972)564-0592 | robp@eldengineering.com | | FORNEY, TX 75126 |
MECH. CTR. | CHAPMAN AIR & HEAT | (214)340-4999 | ascutter@chapmanair.com | | DALLAS, TX 75238 |
PLUM. CONT. | TIM LONG PLUMBING INC | (817)439-3629 | TIMLONG59@CHARTER.NET | SUITE 900 | HASLET, TX 76052 |
STRUCT ENG | ERIC L DAVIS ENGINEERING, INC | (972)564-0592 | ericdavis@eldengineering.com | P O BOX 2637 | FORNEY, TX 75126 |
|
BACK FLOW FORM REVIEW |
$25.00
|
5/31/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
9/26/2013
|
Total Fees |
Charged: $50.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
5/25/2017
| | 5/25/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/3/2016
| | 2/3/2016 | |
More Info
|
BACKFLOW | APPROVED |
9/25/2013
| | 9/25/2013 | |
More Info
|
There are currently no reviews on this record.