Permit Info
Short Description:
2 BF FIRE -PROT 5836 AC, 7164 SF, SFR / 2 STORY
Expiration Date:
2/2/2019
Notes:
2 BF FIRE -PROT 5836 AC, 7164 SF, SFR / 2 STORY
5/20/2013 12:00:00 AM
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
009. BEAMS=10"W X 26"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
025. TEMPERED GLASS REQ'D AT WINDOWS WITHIN 2' OF DOOR OPENINGS.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
031. SIDING DIRECTLY OVER MASONRY AT SECOND STORY IS NOT ALLOWED.
033. MEDIA ROOM WITH CLOTHING STORAGE MUST HAVE A CODE COMPLIANT EGRESS WINDOW.
035. 2 X 6 PLUMBING (VENT STACK/WASTE) WALLS REQ'D AT ALL FIXTURES.
041. DOUBLE UNDERLAYMENT REQUIRED ON COMPOSITION ROOFS WITH A 4:12 PITCH OR LESS-MINIMUM PITCH 2:12.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24".
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
Parcel Info
City/State/Zip:
FRISCO, TX, 75033
Subdivision:
SHADDOCK CREEK ESTATES PH 5
|
BF TESTER | CORBIN MOYER | (817)232-5577 | oneafire@me.com | 301 S. SAGINAW | SAGINAW, TX 76179 |
OWNER | JOHNSTON, JUDITH | ()- | | | FRISCO, TX 75033-0134 |
MAIL TO | JOHNSTON, JUDITH | ()- | | | FRISCO, TX 75033-0134 |
APPLICANT | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
CONTRACTOR | SHADDOCK HOMES LTD | (972)398-4019 | misty@shaddockhomes.com | 2400 Dallas Parkway Suite 510 | PLANO, TX 75093 |
ELECT. CTR. | METRO TECH ELECTRIC | (972)941-8600 | fstory@metrotechelectric.com | | WYLIE, TX 75098 |
FIRE CONTACT | RES COM FIRE SYSTEM | (214)350-1755 | | P O BOX 630886 | IRVING, TX 75063 |
HERS PROVIDE | STRAND SYSTEMS ENG INC | (972)620-8204 | jennifer@stransystems.com | | IRVING, TX 75039 |
MECH. CTR. | K & S HEATING & AIR | (972)271-9319 | dmccord45@yahoo.com | | GARLAND, TX 75041 |
PLUM. CONT. | ENTERPRISE PLUMBING | (972)231-2860 | joed@enterplumb.com | | RICHARDSON, TX 75081 |
STRUCT ENG | CHILDRESS ENGINEERING | (214)451-6630 | TCHILDRESS@CESGLOBAL.COM | 2505 N. PLANO RD #1200 | RICHARDSON, TX 75082 |
|
BACK FLOW FORM REVIEW |
$25.00
|
1/16/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
5/17/2017
|
BACK FLOW FORM REVIEW |
$25.00
|
5/17/2017
|
BACK FLOW FORM REVIEW |
$50.00
|
3/8/2018
|
Total Fees |
Charged: $125.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
2/28/2018
| | 2/28/2018 | |
More Info
|
BACKFLOW | APPROVED |
2/28/2018
| | 2/28/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/17/2017
| | 5/17/2017 | |
More Info
|
BACKFLOW | APPROVED |
5/17/2017
| | 5/17/2017 | |
More Info
|
BACKFLOW | APPROVED |
2/2/2016
| | 2/2/2016 | |
More Info
|
BACKFLOW | APPROVED |
1/7/2014
| | 1/7/2014 | |
More Info
|
There are currently no reviews on this record.