Permit Info
Short Description:
1 BF FIRE PROT - 4893 AC, 6257 SF, SFR / 2 STORY
Expiration Date:
3/3/2019
Notes:
1 BF FIRE PROT - 4893 AC, 6257 SF, SFR / 2 STORY
12/16/2013 12:00:00 AM
001. COMPLIANCE WITH THE AMENDED (06/18/13) ZONING ORDINANCE.
002. COMPLIANCE WITH THE 2006 BUILDING CODES, AMENDMENT AND PLANNED DEVELOPMENT REQUIREMENTS.
003. TERMITE PROTECTION REQ'D AT ALL SLAB PENETRATIONS.
008. BEAMS=10"W X 24"D.
022. SEE ENCLOSED SHEET FOR WOOD FENCE CONSTRUCTION.
029. TEMPERED GLASS AT FLOAT GLASS WINDOWS GREATER THAN 9 SQ FT, LESS THAN 18" OFF FINISH FLOOR, WITHIN 3'-0" OF A WALKING SURFACE.
039. RESIDENTIAL STUCCO REQUIRES LATH & EXPANDED WIRE MESH WITH CEMENT PLASTER.
042. THIS SUBDIVISION MAY REQUIRE H.O.A. DESIGN APPROVAL PRIOR TO PLAN SUBMITTAL AND CONSTRUCTION.
044. CO DETECTORS REQ'D ON ELECTRICAL LEGEND & ELECTRICAL PLAN 1/1000 SQ. FT. & 1 PER FLOOR MINIMUM WITH (1) ON THE AC SIDE OF THE GARAGE DOOR.
046. FRONT ENTRY CURB CUT PER ENCLOSED DESIGN SKETCH WITH DRIVEWAY MAXIMUM WIDTH 24 FEET.
048. LANDSCAPE IRRIGATION SYSTEM, IF INSTALLED, REQUIRES DESIGN APPROVAL PRIOR TO REQUEST FOR FINAL INSPECTION (CO).
049. GREEN BUILDING VENTILATION REQUIREMENT BASED ON ASHARAE 62.2 STANDARD.
050. ET BASED CONTROLLER REQUIRED FOR AUTOMATIC IRRIGATION SYSTEMS PER CITY ORDINANCE ZA06-0005 DATED 11/24/2006.
054. PROVIDE EXPANSION JOINTS IN MASONARY FACADE.
057. AUTOMATIC FIRE PROTECTION SPRINKLERS REQ'D W/ DESIGN & INSTALLATION APPROVED BY FIRE MARSHAL.
059. INCLUDED IN THIS PERMIT PACK IS THE REQUIRED BARRIER-FREE RAMP; USE THE APPROPRIATE DETAIL FIGURE 1 OR 1a.
Parcel Info
City/State/Zip:
FRISCO, TX, 75035
Subdivision:
RICHWOODS #12 (CFR)
|
BF TESTER | ALFRED D. GAINES | (972)292-1452 | | 1040 WAGON TRAIL | LITTLE ELM, TX 75068 |
OWNER | HUANG TIANZHOU & | ()- | | XIAOQING FANG | FRISCO, TX 75035-0620 |
MAIL TO | HUANG TIANZHOU & XIAOQING FANG | ()- | rvanderheiden@tollbrothersinc.com | | FRISCO, TX 75035 |
APPLICANT | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 Vita Dolce | Frisco, TX 75034 |
CONTRACTOR | TOLL BROTHERS INC | (469)525-0524 | rvanderheiden@tollbrothersinc.com | 9178 Vita Dolce | Frisco, TX 75034 |
ELECT. CTR. | IES RESIDENTIAL INC | (972)562-7724 | brian.hartley@ies-co.com | | MCKINNEY, TX 75069 |
FIRE CONTACT | GS FIRE PROTECTION, LLC | (214)708-7289 | rfrost@gsfireprotectionllc.com | 125 Richardson | ALLEN, TX 75002 |
HERS PROVIDE | ENERGY INSPECTORS of TEXAS | (469)441-9795 | JMCDONALD@ENERGYINSPECTOR.COM | | MCKINNEY, TX 75071 |
MECH. CTR. | RELIANT HEATING AND AIR CONDIT | (817)616-1100 | ahinson@reliantac.com | PO BOX 166169 | IRVING, TX 75016 |
PLUM. CONT. | HORIZON PLUMBING | (817)461-1117 | JSANCHEZ@HORIZONPLUMBING.NET | | ARLINGTON, TX 76013 |
STRUCT ENG | D & E STRUCTURES CONSULTING EN | (214)741-3095 | SDICKSON@DE-STRUCTURES.COM | STE. 760 | DALLAS, TX 75201 |
|
BACK FLOW FORM REVIEW |
$25.00
|
4/16/2018
|
BACK FLOW FORM REVIEW |
$25.00
|
5/5/2014
|
BACK FLOW FORM REVIEW |
$25.00
|
5/12/2017
|
Total Fees |
Charged: $75.00
Balance Due: $0.00
|
|
BACKFLOW | APPROVED |
4/6/2018
| | 4/6/2018 | |
More Info
|
BACKFLOW | APPROVED |
5/8/2017
| | 5/8/2017 | |
More Info
|
BACKFLOW | APPROVED |
3/3/2016
| | 3/3/2016 | |
More Info
|
BACKFLOW | APPROVED |
4/25/2014
| | 4/25/2014 | |
More Info
|
There are currently no reviews on this record.